3+ Million Parts
365 Day Returns
Fast 2-4 Day Shipping

Suttner Pressure Washer Unloader

Suttner Pressure Washer Unloader Parts

Suttner Pressure Washer Unloader: Jacks is your Place! We have the Pressure Washer Unloader you need, with fast shipping and great prices! For lawn mower parts and accessories, think Jacks!

Featured: 15  Items
Sort by
Result's per page
 

ST 261 S Unloader with Switch

Barens OEM Part
Part Number: 2379
 
Specs
Equipment Type Pressure Washer
PSI 3650
Inlet 3/8" FPT
Outlet 3/8" FPT
Guage Port: 1/4" FPT
Switch Specs: 5A @ 125 VAC or 3A @ 250 VAC
Regulating unloader valve Tamper resistant operator adjustable valve which allows limit setting on both maximum and minimum pressure Ideal for steam combination applications Straight flow-through design minimizes pressure loss through valve Working components constructed of high grade stainless steel, teflon, and Viton seals for maximum heat/chemical resistance Internal bypass valve can be easily accessed and repaired without removing unloader from unit True to Suttner design tradition, valve is cartridge type and installed in minutes Pressure adjustment knob can be removed if desired
The micro switch is an STSP-NC A.C. switch mounted in the place of the bypass fitting. The switch allows the actuation of solenoids, display lights, timers, or other electrical devices. Switch wired "Normally Closed" and is opened by the unloader piston during the bypass mode. The switch is ideal for solenoid activation, time delay shutdown systems, swquencers, and other related systems
Temperature 176°F
Gallons Per Minute 8.0

Fits Model
SUTTNER : ST-261 With Micro Switch

Replaces OEM
Suttner :
Your Price:
$179.87
Qty:

ST 261 I Unloader With Injector

Barens OEM Part
Part Number: 1453
 
Specs
Equipment Type Pressure Washer
Orifice 2.1mm
PSI 3650
Gallons Per Minute 2.25 to 3.35
Inlet 3/8" FPT
Outlet 3/8" FPT
Weight 22.5 oz
Gauge: 1/4" FPT
Bypass: 1/4" FPT
Regulating unloader valve Tamper resistant operator adjustable valve which allows limit setting on both maximum and minimum pressure Ideal for steam combination applications Straight flow-through design minimizes pressure loss through valve Working components constructed of high grade stainless steel, teflon, and Viton seals for maximum heat/chemical resistance Internal bypass valve can be easily accessed and repaired without removing unloader from unit True to Suttner design tradition, valve is cartridge type and installed in minutes Pressure adjustment knob can be removed if desired
Downstream injection at 10:1 rate Low pressure limit setting eliminates need of additional metering devices A downstream chemical injector relies on pressure loss through a restrictive orifice, which is built in on the ST-261 restriction AFTER the orifice must be minimized in order for injection to occur. Therefore, this system must incorporate a large orifice spray nozzle which reduces such restriction. It is generally recommended the usage of a nozzle with a minimum orice size of 30.0. Samller nozzles may be used, but the added restriction may result in ineffective suction rates or no suction at all. In addition, remember that fittings and even hose add to the restriction within the system and may affect or eliminate the suction capabilities
Temperature 176°F

Fits Model

Replaces OEM
Suttner :
Your Price:
$121.70
Qty:

ST 261 Pressure Actuated Unloader

Barens OEM Part
Part Number: 1396
 
Specs
Equipment Type Pressure Washer
PSI 3625
Inlet 3/8" FPT
Outlet 3/8" FPT
1/4" FPT Bypass
Can be Panel Mounted
Gauge Port: 1/4" FPT
Tamper resistant operator adjustment valve allows limit setting on both maximum and minimum pressure. Ideal for steam combination operations. Straight flow-through design minimizes pressure loss through valve. Working components constructed of high grade stainless steel, teflon, and Viton seals for maximum heat/chemical resistance. Internal bypass valve can be easily accessed and repaired without removing unloader from unit. True to Suttner design tradition, valve is cartridge type and installed in minutes.Pressure adjustment knob can be removed if desired.
Temperature 176°F
Gallons Per Minute 8.0

Fits Model
SUTTNER : ST-261

Replaces OEM
Suttner :
Your Price:
$107.05
Qty:

ST 261 I Unloader with Injector

Barens OEM Part
Part Number: 1397
 
Specs
Equipment Type Pressure Washer
Orifice 2.4mm
PSI 3650
Gallons Per Minute 3.35 to 5.00
Inlet 3/8" FPT
Outlet 3/8" FPT
Weight 22.5 oz
Bypass: 1/4" FPT
Gauge: 1/4" FPT
Regulating unloader valve Tamper resistant operator adjustable valve which allows limit setting on both maximum and minimum pressure Ideal for steam combination applications Straight flow-through design minimizes pressure loss through valve Working components constructed of high grade stainless steel, teflon, and Viton seals for maximum heat/chemical resistance Internal bypass valve can be easily accessed and repaired without removing unloader from unit True to Suttner design tradition, valve is cartridge type and installed in minutes Pressure adjustment knob can be removed if desired
Downstream injection at 10:1 ratio Low pressure limit setting eliminates the need of additional metering devices Relies on pressure loss through a restrictive orifice, which is built-in on the ST-261. Restriction AFTER the orifice must be minimized in order for injection to occur. Therefore, this system must incorporate a large orifice spray nozzle which reduces such restriction. The usage of a nozzle with a minimum orifice size of 30.0 is recommended. A smaller nozzle may be used, but the added restriction may result in ineffective suction rates or no suction at all. In addition, remember that elbow, fittings, and enen hose add to the restriction within the system and may affect or eliminate the suction capabilities
Temperature 176°F

Fits Model

Replaces OEM
Suttner :
Your Price:
$121.70
Qty:

ST 291 Pressure Actuated Unloader

Barens OEM Part
Part Number: 6647
 
Specs
Equipment Type Pressure Washer
Inlet 3/8" FPT
Outlet 3/8" FPT
PSI 5070
1/2" FPT Bypass
Pressure regulator, adjustable from 850 PSI to 5070 PSI
Temperature 176°F
Gallons Per Minute 8.0

Fits Model
SUTTNER : ST-291

Replaces OEM
Suttner :
Your Price:
$332.46
Qty:

ST 261 Unloader with Injector

Barens OEM Part
Part Number: 1452
 
Specs
Equipment Type Pressure Washer
PSI 3650
Gallons Per Minute 1.5 to 2.25
Inlet 3/8" FPT
Outlet 3/8" FPT
Weight 22.5 oz
Bypass: 1/4" FPT
Gauge Port: 1/4" FPT
Regulating unloader valve Tamper resistant operator adjustable valve which allows limit setting on both maximum and minimum pressure Ideal for steam combination applications Straight flow-through design minimizes pressure loss through valve Working components constructed of high grade stainless steel, teflon, and Viton seals for maximum heat/chemical resistance Internal bypass valve can be easily accessed and repaired without removing unloader from unit True to Suttner design tradition, valve is cartridge type and installed in minutes Pressure adjustment knob can be removed if desired
Downstream injection at 10:1 rate Low pressure limit setting eliminates need of additional metering devices A downstream chemical injector relies on pressure loss through a restrictive orifice, which is built in on the ST-261 restriction AFTER the orifice must be minimized in order for injection to occur. Therefore, this system must incorporate a large orifice spray nozzle which reduces such restriction. It is generally recommended the usage of a nozzle with a minimum orice size of 30.0. Samller nozzles may be used, but the added restriction may result in ineffective suction rates or no suction at all. In addition, remember that fittings and even hose add to the restriction within the system and may affect or eliminate the suction capabilities
Temperature 176°F
Orifice 1.8mm

Fits Model

Replaces OEM
Suttner :
Your Price:
$121.70
Qty:

ST 280 Pressure Actuated Unloader

Barens OEM Part
Part Number: 3710
 
Specs
Equipment Type Pressure Washer
PSI 3600
Inlet 3/8" FPT
Outlet 3/8" FPT
Bypass: 1/4" FPT
Temperature 176°F
Gallons Per Minute 8.0

Fits Model
SUTTNER : ST-280

Replaces OEM
Suttner :
Your Price:
$131.25
Qty:

Complete Switch Assembly for ST 261 Unloader

Barens OEM Part
Part Number: 3847
 
Specs
Equipment Type Pressure Washer
The microswitch is an STSP-NC A.C. switch. Mounted in place of the bypass on the ST-261 unloader, the switch allows the actuation of solenoids, display lights, timers, or other electrical devices. The switch is wired "Normally Closed" and is opened by the unooader piston during the bypass mode. The switch is ideal for solenoid activation, time delay shutdown systems, swquencers, and other related systems.

Fits Model

Replaces OEM
Suttner :
Your Price:
$99.13
Qty:

Valve Kit 200261526 for Pressure Washer Unloader

Barens OEM Part
Part Number: 4655
 
Specs
Equipment Type Pressure Washer

Fits Model
SUTTNER : ST-261

Replaces OEM
Suttner :
Your Price:
$61.05
Qty:

Panel Mount Nut for ST-261 Unloaders

Barens OEM Part
Part Number: 5374
 
Specs
Equipment Type Pressure Washer

Fits Model
SUTTNER : ST-261

Replaces OEM
Suttner :
Your Price:
$12.74
Qty: