3+ Million Parts
365 Day Returns
Fast 2-4 Day Shipping

General Pump Flow Actuated Unloader

General Pump - Pressure Washer Unloader - Flow Actuated Unloader

Flow Actuated Unloaders detect the flow of water. If the flow decreases between the pump and the spray gun, this type of unloader will kick into bypass mode to redirect the water back to the inlet of the pump.

Featured: 20  Items
Sort by
Result's per page
 

K5.2 Series Flow Actuated Unloaders

Barens OEM Part
Part Number: 1599
 
Specs
Equipment Type Pressure Washer
PSI 3000
Inlet 3/8" FPT
Outlet 3/8" MPT
Size 6.31" x 4.00" x 2.75"
Bypass Port 3/4" MPT
Discharge Pressure 1450 TO 2900 PSI
This unloading valve is a flow-through design and should be mounted on the discharge line of the pump in any position (vertical or horizontal) which allows easy access to the adjusting bolt. A pressure gauge should be installed on either side of the port of the unloader to accurately read pressure during adjustment. Minimum 5% bypass is required for proper operation. Features all stainless and brass internal parts. No external moving parts or springs. Unique balance principle: eliminates high pressure in all lines while unit is in bypass mode. Elimiates pressure peaks normally generated by conventionally designed unloaders. Dual gauge ports Flow actuated unloaders are activated when the trigger of the gun is released and the flow stops. Pressure between the pump and gun is reduced to near zero pressure.
Gallons Per Minute 4.2 to 6.6
Temperature 165°F
Weight 2.3 lbs

Fits Model

Replaces OEM
General Pump :
Your Price:
$231.31
Qty:

K7.1 Series Flow Actuated Unloaders

Barens OEM Part
Part Number: 1393
 
Specs
Equipment Type Pressure Washer
Gallons Per Minute 3.0 to 4.2
Inlet 3/8" FPT
Outlet 3/8" MPT
Size 7.50" x 3.75" x 3.50"
Bypass Port 3/8" FPT
This unloading valve is a flow-through design and should be mounted on the discharge line of the pump in any position (vertical or horizontal) which allows easy access to the adjusting bolt. A pressure gauge should be installed on either side of the port of the unloader to accurately read pressure during adjustment. Minimum 5% bypass is required for proper operation. Features all stainless and brass internal parts. No external moving parts or springs. Unique balance principle: eliminates high pressure in all lines while unit is in bypass mode. Elimiates pressure peaks normally generated by conventionally designed unloaders. Dual gauge ports
PSI 3500
Temperature 165°F
Weight 4.5 lbs

Fits Model

Replaces OEM
General Pump :
Your Price:
$277.29
Qty:

K7.3 Series Flow Actuated Unloaders

Barens OEM Part
Part Number: 1395
 
Specs
Equipment Type Pressure Washer
Inlet 3/8" FPT
Outlet 3/8" MPT
Size 7.50" x 3.75" x 3.50"
Bypass Port 3/8" FPT
This unloading valve is a flow-through design and should be mounted on the discharge line of the pump in any position (vertical or horizontal) which allows easy access to the adjusting bolt. A pressure gauge should be installed on either side of the port of the unloader to accurately read pressure during adjustment. Minimum 5% bypass is required for proper operation. Features all stainless and brass internal parts. No external moving parts or springs. Unique balance principle: eliminates high pressure in all lines while unit is in bypass mode. Elimiates pressure peaks normally generated by conventionally designed unloaders. Dual gauge ports.
PSI 3500
Weight 4.5 lbs
Temperature 165°F

Fits Model

Replaces OEM
General Pump :
Your Price:
$277.29
Qty:

K5.1E UNLOADER 3.0 4.

Barens OEM Part
Part Number: 1494
 
Specs
Equipment Type Pressure Washer
PSI 3000
Inlet 3/8" FPT
Outlet 3/8" MPT
Size 6.31" x 4.00" x 2.75"
Bypass Port 1/2" FPT & 3/4" MPT
Discharge Pressure 1450 TO 2900 PSI
This unloading valve is a flow-through design and should be mounted on the discharge line of the pump in any position (vertical or horizontal) which allows easy access to the adjusting bolt. A pressure gauge should be installed on either side of the port of the unloader to accurately read pressure during adjustment. Minimum 5% bypass is required for proper operation. Features all stainless and brass internal parts. No external moving parts or springs. Unique balance principle: eliminates high pressure in all lines while unit is in bypass mode. Elimiates pressure peaks normally generated by conventionally designed unloaders. Dual gauge ports Flow actuated unloaders are activated when the trigger of the gun is released and the flow stops. Pressure between the pump and gun is reduced to near zero pressure.
For European Style Pressure Washers
Gallons Per Minute 3.0 to 4.2
Temperature 165°F
Weight 2.3 lbs

Fits Model

Replaces OEM
General Pump :
Your Price:
$231.31
Qty:

K5.3 Series Flow Actuated Unloaders

Barens OEM Part
Part Number: 1751
 
Specs
Equipment Type Pressure Washer
PSI 3000
Inlet 3/8" FPT
Outlet 3/8" MPT
Size 6.31" x 4.00" x 2.75"
Bypass Port 3/4" MPT
Discharge Pressure 1450 TO 2900 PSI
This unloading valve is a flow-through design and should be mounted on the discharge line of the pump in any position (vertical or horizontal) which allows easy access to the adjusting bolt. A pressure gauge should be installed on either side of the port of the unloader to accurately read pressure during adjustment. Minimum 5% bypass is required for proper operation. Features all stainless and brass internal parts. No external moving parts or springs. Unique balance principle: eliminates high pressure in all lines while unit is in bypass mode. Elimiates pressure peaks normally generated by conventionally designed unloaders. Dual gauge ports Flow actuated unloaders are activated when the trigger of the gun is released and the flow stops. Pressure between the pump and gun is reduced to near zero pressure.
Gallons Per Minute 6.6 to 10
Weight 2.3 lbs
Temperature 165°F

Fits Model

Replaces OEM
General Pump :
Your Price:
$231.31
Qty:

K3.0E Series Flow Actuated Unloaders

Barens OEM Part
Part Number: 2347
 
Specs
Equipment Type Pressure Washer
PSI 1450
Inlet 3/8" FPT
Outlet 3/8" MPT
Size 5.75" x 3.50" x 2.75"
This unloading valve is a flow-through design and should be mounted on the discharge line of the pump in any position (vertical or horizontal) which allows easy access to the adjusting bolt. A pressure gauge should be installed on either side of the port of the unloader to accurately read pressure during adjustment. Minimum 5% bypass is required for proper operation. Features all stainless and brass internal parts. No external moving parts or springs. Unique balance principle: eliminates high pressure in all lines while unit is in bypass mode. Elimiates pressure peaks normally generated by conventionally designed unloaders. Dual gauge ports
Flow actuated unloaders are activated when the trigger of the gun is released and the flow stops. Pressure between the pump and gun is reduced to near zero pressure.
Bypass Port 3/4" MPT & 1/2" F
Discharge Pressure 0 to 1450 PSI
Gallons Per Minute 2.1 to 3.0
Temperature 165°F

Fits Model

Replaces OEM
General Pump :
Your Price:
$217.87
Qty:

K7 Series Flow Actuated Unloaders

Barens OEM Part
Part Number: 1220
 
Specs
Equipment Type Pressure Washer
Gallons Per Minute 2.1 to 3.0
Inlet 3/8" FPT
Outlet 3/8" MPT
Size 7.50" x 3.75" x 3.50"
Bypass Port 3/8" FPT
This unloading valve is a flow-through design and should be mounted on the discharge line of the pump in any position (vertical or horizontal) which allows easy access to the adjusting bolt. A pressure gauge should be installed on either side of the port of the unloader to accurately read pressure during adjustment. Minimum 5% bypass is required for proper operation. Features all stainless and brass internal parts. No external moving parts or springs. Unique balance principle: eliminates high pressure in all lines while unit is in bypass mode. Elimiates pressure peaks normally generated by conventionally designed unloaders. Dual gauge ports.
PSI 3500
Temperature 165°F
Weight 4.5 lbs

Fits Model

Replaces OEM
General Pump :
Your Price:
$277.29
Qty:

K7.2 Series Flow Actuated Unloaders

Barens OEM Part
Part Number: 1394
 
Specs
Equipment Type Pressure Washer
Inlet 3/8" FPT
Outlet 3/8" MPT
Size 7.50" x 3.75" x 3.50"
Bypass Port 3/8" FPT
This unloading valve is a flow-through design and should be mounted on the discharge line of the pump in any position (vertical or horizontal) which allows easy access to the adjusting bolt. A pressure gauge should be installed on either side of the port of the unloader to accurately read pressure during adjustment. Minimum 5% bypass is required for proper operation. Features all stainless and brass internal parts. No external moving parts or springs. Unique balance principle: eliminates high pressure in all lines while unit is in bypass mode. Elimiates pressure peaks normally generated by conventionally designed unloaders. Dual gauge ports.
Gallons Per Minute 4.2 to 6.6
PSI 3500
Temperature 165°F
Weight 4.5 lbs

Fits Model

Replaces OEM
General Pump :
Your Price:
$277.29
Qty:

K3 Series Flow Actuated Unloaders

Barens OEM Part
Part Number: 1593
 
Specs
Equipment Type Pressure Washer
PSI 1450
Inlet 3/8" FPT
Outlet 3/8" MPT
Size 5.75" x 3.50" x 2.75"
Bypass Port 3/4" MPT
This unloading valve is a flow-through design and should be mounted on the discharge line of the pump in any position (vertical or horizontal) which allows easy access to the adjusting bolt. A pressure gauge should be installed on either side of the port of the unloader to accurately read pressure during adjustment. Minimum 5% bypass is required for proper operation. Features all stainless and brass internal parts. No external moving parts or springs. Unique balance principle: eliminates high pressure in all lines while unit is in bypass mode. Elimiates pressure peaks normally generated by conventionally designed unloaders. Dual gauge ports
Flow actuated unloaders are activated when the trigger of the gun is released and the flow stops. Pressure between the pump and gun is reduced to near zero pressure.
Discharge Pressure 0 to 1450 PSI
Gallons Per Minute 2.1 to 3.0
Temperature 165°F

Fits Model

Replaces OEM
General Pump :
Your Price:
$217.87
Qty:

K3.1 Series Flow Actuated Unloaders

Barens OEM Part
Part Number: 1594
 
Specs
Equipment Type Pressure Washer
PSI 1450
Inlet 3/8" FPT
Outlet 3/8" MPT
Size 5.75" x 3.50" x 2.75"
This unloading valve is a flow-through design and should be mounted on the discharge line of the pump in any position (vertical or horizontal) which allows easy access to the adjusting bolt. A pressure gauge should be installed on either side of the port of the unloader to accurately read pressure during adjustment. Minimum 5% bypass is required for proper operation. Features all stainless and brass internal parts. No external moving parts or springs. Unique balance principle: eliminates high pressure in all lines while unit is in bypass mode. Elimiates pressure peaks normally generated by conventionally designed unloaders. Dual gauge ports
Flow actuated unloaders are activated when the trigger of the gun is released and the flow stops. Pressure between the pump and gun is reduced to near zero pressure.
Bypass Port 3/4" MPT
Discharge Pressure 0 to 1450 PSI
Gallons Per Minute 3.0 to 4.2
Temperature 165°F

Fits Model

Replaces OEM
General Pump :
Your Price:
$217.87
Qty: