Clean Cut Fuel Pumps: These Clean Cut Fuel Pumps are built with a solenoid valve that has the hefty lift capabilities of traditional American pumps. The clean cut design reduces demands on the motor at start-up by allowing the oil to freely pass through the pump’s pistons. Check out Jack's selection below!

Featured: 3  Items
Sort by
Result's per page
 

240 Volt Clean Cut Fuel Pump

Barens OEM Part
Part Number: 6564
 
Specs
Equipment Type Pressure Washer
The oil pump for the 21st century
Developed in co-operation with SunTec Industries, combines the clean burning benefits of a solenoid valve with the hefty lift capabilities of traditional American pumps. The solenoid valve cuts the oil flow almost instantly when power is cut to the motor, eliminating coasting stops that can cause soot formation on shut-down.
There are few moving parts compared to conventional pumps and fewer troublesome oil fittings to cause problems. the clean cut reduces demands on the motor during start-up by allowing oil to freely bypass the pump's pistons.
Clean cut pumps utilizes the same piston valve used in traditional pumps to provide the same level of protection from leak through in gravity feed situations.
NOTE:The clean cut is designed to be operated with modern electronic controls and must be used with a pre-purge or "valve-on" delay, such as Beckett PD Timer. Controls without a delay will produce hard starts.
HYDRAULIC DATA: Nozzle Pressure Range: 100-200 PSI, Factory Set Pressure: 100 PSI, Operating Fluids: #2 and lighter fuel oils, viscosity 1.4-12cSt, 0-25 degrees C/32-77 degrees F in the pump, Inlet Pressure: 10 PSI maximum, Return Pressure: 10 PSI maximum, Suction Height: One pipe: 8' maximum Two pipe: 14' maximum, Rated Speed: 3600 RPM maximum, Breakaway Torque: 36" oz. maximum
SOLENOID VALVE CHARACTERISTICS: Voltage: 24, 200-240 VAC, 60/50Hz, Power consumption: 9 Watts, Ambient Temperature: 155 degrees F./46 degrees C, Maximum Pressure: 200 PSI, Certification: UL, CUL (50 Hz not UL certified)

Fits Model
UNIVERSAL : 240 Volt Pump

Replaces OEM
Universal :
Your Price:
$187.75
Qty:

12 Volt Clean Cut Fuel Pump

Barens OEM Part
Part Number: 6588
 
Specs
Equipment Type Pressure Washer
Developed in co-operation with SunTec Industries, combines the clean burning benefits of a solenoid valve with the hefty lift capabilities of traditional American pumps. The solenoid valve cuts the oil flow almost instantly when power is cut to the motor, eliminating coasting stops that can cause soot formation on shut-down.
There are few moving parts compared to conventional pumps and fewer troublesome oil fittings to cause problems. the clean cut reduces demands on the motor during start-up by allowing oil to freely bypass the pump's pistons.
Clean cut pumps utilizes the same piston valve used in traditional pumps to provide the same level of protection from leak through in gravity feed situations.
NOTE:The clean cut is designed to be operated with modern electronic controls and must be used with a pre-purge or "valve-on" delay, such as Beckett PD Timer. Controls without a delay will produce hard starts.
SOLENOID VALVE CHARACTERISTICS: Voltage: 24, 12VDC, Power consumption: 9 Watts, Ambient Temperature: 155 degrees F./46 degrees C., Maximum Pressure: 200 PSI, Certification: UL, CUL (50 Hz not UL certified)
Nozzle Pressure Range: 100-200 PSI, Factory Set Pressure: 100 PSI, Operating Fluids: #2 and lighter fuel oils, viscosity 1.4-12cSt, 0-25 degrees C/32-77 degrees F in the pump, Inlet Pressure: 10 PSI maximum, Suction Height: One pipe: 8' maximum Two pipe: 14' maximum, Rated Speed: 3600 RPM maximum, Breakaway Torque: 36" oz. maximum

Fits Model
UNIVERSAL : 12 Volt Pumps

Replaces OEM
Universal :
Your Price:
$185.53
Qty:

120 Volt Clean Cut Fuel Pump

Barens OEM Part
Part Number: 6591
 
Specs
Equipment Type Pressure Washer
Developed in co-operation with SunTec Industries, combines the clean burning benefits of a solenoid valve with the hefty lift capabilities of traditional American pumps. The solenoid valve cuts the oil flow almost instantly when power is cut to the motor, eliminating coasting stops that can cause soot formation on shut-down.
There are few moving parts compared to conventional pumps and fewer troublesome oil fittings to cause problems. the clean cut reduces demands on the motor during start-up by allowing oil to freely bypass the pump's pistons.
Clean cut pumps utilizes the same piston valve used in traditional pumps to provide the same level of protection from leak through in gravity feed situations.
NOTE:The clean cut is designed to be operated with modern electronic controls and must be used with a pre-purge or "valve-on" delay, such as Beckett PD Timer. Controls without a delay will produce hard starts.
HYDRAULIC DATA: Nozzle Pressure Range: 100-200 PSI, Factory Set Pressure: 100 PSI, Operating Fluids: #2 and lighter fuel oils, viscosity 1.4-12cSt, 0-25 degrees C/32-77 degrees F in the pump, Inlet Pressure: 10 PSI maximum, Return Pressure: 10 PSI maximum, Suction Height: One pipe: 8' maximum Two pipe: 14' maximum, Rated Speed: 3600 RPM maximum, Breakaway Torque: 36" oz. maximum,
SOLENOID VALVE CHARACTERISTICS: Voltage: 24, 110-120VAC, 60/50Hz, Power consumption: 9 Watts, Ambient Temperature: 155 degrees F./46 degrees C, Maximum Pressure: 200 PSI, Certification: UL, CUL (50 Hz not UL certified)

Fits Model
UNIVERSAL : 120 Volt Pumps

Replaces OEM
Universal :
Your Price:
$172.44
Qty: