Specs |
Equipment Type Pressure Washer
PSI 3200
Gallons Per Minute 3.7
Weight 16 lbs
Inlet Dual 1/2" BSP
Outlet Dual 3/8" BSP
Maximum Pump Speed: 3450 RPM
Minimum Horsepower Required: 9.2 bhp (11.9 hp for gas engines)
Plunger Diameter: 12mm
Stroke: 14.1mm
Temperature 160° F
Lubrication: prior to initial operation add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL. Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.
Type Hollow Shaft Pump
Shaft Size 24mm (.945")
|
Fits Model |
GIANT PUMP : P317RX
|
Replaces OEM |
Giant Pump :
|
|
|
|
|
Specs |
Equipment Type Pressure Washer
PSI 2000
Gallons Per Minute 3.3
Weight 11 lbs
Minimum Horsepower Requirements: 5.8 bhp (8.7 hp for gas engines)
Plunger Diameter: 18mm
Stroke: 5.5mm
Maximum Temperature: 160° Degrees F.
Fluid End: Brass
Gear End: Aluminum
Valves: Stainless Steel
Inlet Dual 1/2" BSP
Outlet Dual 3/8" BSP
Lubrication: Prior to initial operration, add oil to crankcase so that oil level is between the two lines on the dipstick. DO NOT OVERFILL. Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.
Type Hollow Shaft Pump
Shaft Size 24mm (.945")
|
Fits Model |
GIANT PUMP : P17RX
|
Replaces OEM |
Giant Pump :
|
|
|
|
|
Specs |
Equipment Type Pressure Washer
PSI 2000
Gallons Per Minute 3.18
Weight 12 lbs
Inlet Dual 1/2" BSP
Outlet Dual 3/8" BSP
Maximum Pump Speed: 1750 RPM
Minimum Horsepower Requirements: 5.9 bhp (7.6 hp for gas engines)
Plunger Diameter: 18mm
Stroke: 10mm
Maximum Temperature: 160° Degrees F
Lubrication: Prior to initial operation, add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL. Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending upon operating conditions.
Type Hollow Shaft Pump
Shaft Size 24mm (.945")
|
Fits Model |
GIANT PUMP : P218
|
Replaces OEM |
Giant Pump :
|
|
|
|
|
Specs |
Equipment Type Pressure Washer
PSI 2000
Gallons Per Minute 4.2
Weight 12 lbs
Inlet Dual 1/2" BSP
Outlet Dual 3/8" BSP
Maximum Pump Speed: 1750 RPM
Minimum Horsepower Requirements: 7.2 bhp (9.3 hp for gas engines)
Plunger Diameter: 18mm
Stroke: 12.4mm
Maximum Temperature: 160° Degrees F
Lubrication: Prior to initial operation, add oil to crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL. Crankcase oil should be changed after the first 50 hours of operation, than at regular intervals of 500 hours or less depending on operating conditions.
Type Hollow Shaft Pump
Shaft Size 24mm (.945")
|
Fits Model |
GIANT PUMP : P219RX
|
Replaces OEM |
Giant Pump :
|
|
|
|
|
Specs |
Equipment Type Pressure Washer
PSI 3200
Gallons Per Minute 3.8
Weight 16 lbs
Inlet Dual 1/2" BSP
Outlet Dual 3/8" BSP
Silverline Triplex Plunger Pump. Stainless steel and brass wetted parts. Solid ceramic plungers.
Maximum Pump Speed: 3450 RPM
Minimum Horsepower Required: 9.2 bhp (11.9 hp for gas engines)
Plunger Diameter: 12mm
Stroke: 14.1mm
Temperature 160° F
Lubrication: prior to initial operation add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL. Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.
Type Hollow Shaft Pump
Shaft Size 24mm (.945")
|
Fits Model |
GIANT PUMP : P321R
|
Replaces OEM |
Giant Pump :
|
|
|
|
|
Specs |
Equipment Type Pressure Washer
PSI 3000
Gallons Per Minute 4.7
Weight 16 lbs
Outlet Dual 3/8" BSP
Inlet Dual 1/2" BSP
Stainless steel and brass wetted parts. Solid ceramic plungers.
Maximum Pump Speed: 1750 RPM
Minimum Horsepower Requirements: 9.7 bhp (14.6 hp for gas engines)
Right handed shaft with short backend
Plunger Diameter: 18mm
Stroke: 14.1mm
Maximum Temperature: 160° Degrees F.
Lubrication: prior to initial operation add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL. Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.
Type Hollow Shaft Pump
Shaft Size 24mm (.945")
|
Fits Model |
GIANT PUMP : P316RX
|
Replaces OEM |
Giant Pump :
|
|
|
|
|
Specs |
Equipment Type Pressure Washer
PSI 2200
Weight 16 lbs
Gallons Per Minute 4.1
Maximum Pump Speed: 3450 RPM
Minimum Horsepower Requirements: 6.0 bhp (7.8 hp for gas engines)
Plunger Diameter: 20mm
Stroke: 16mm
Inlet Dual 1/2" BSP
Dual 3/8" BSP
Lubrication: Prior to initial operation, add oiil to the crankcase so that the oil level is between the two lines on the oil dipstick. DO NOT OVERFILL. Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less depending on operating conditions.
Type Hollow Shaft Pump
Shaft Size 24mm (.945")
|
Fits Model |
GIANT PUMP : P318R
|
Replaces OEM |
Giant Pump :
|
|
|
|
|
Specs |
Equipment Type Pressure Washer
PSI 1700
Shaft Size 28mm
Weight 37 lbs
Inlet Dual 3/4" FPT
Outlet Dual 3/4" FPT
Minimum Horsepower Requirements: 15.1 bhp (19.7 hp for gas engines)
Plunger Diameter: 25mm
Stroke: 24mm
Maximum Temperature: 160° Degrees F
Lubrication: Prior to inital operation, add oil to crankcase so that the oil level is between the two lines on the oil dipstick. DO NOT OVERFILL. Crankcase oil should be changed after the first 50 hours of operation, then in regular intervals of 500 hours or less depending on operating conditions.
Type Hollow Shaft Pump
Gallons Per Minute 13
|
Fits Model |
GIANT PUMP : P420A
|
Replaces OEM |
Giant Pump :
|
|
|
|
|
Specs |
Equipment Type Pressure Washer
PSI 1900
Gallons Per Minute 6.1
Weight 18 lbs
Inlet Dual 1/2" BSP
Outlet Dual 3/8" BSP
Maximum Pump Speed: 1420 RPM
Minimum Horsepower Requirements: 9.7 bhp (12.6 hp for gas engines)
Shaft Diameter: 22mm
Plunger Diameter: 20mm
Stroke: 18.1mm
Maximum Temperature: 160° Degrees F
Lubrication: Prior to initial operation, add oil to crankcase so that oil level is between two lines on the oil dipstick. DO NOT OVERFILL. Crankcase oil should be changed after the first 50 hours of operation, then in regular intervals of 500 hours or less depending on operating conditions.
Type Hollow Shaft Pump
Shaft Size 24mm (.945")
|
Fits Model |
GIANT PUMP : P56W
|
Replaces OEM |
Giant Pump :
|
|
|
|
|
Specs |
Equipment Type Pressure Washer
PSI 3000
Gallons Per Minute 4.7
Weight 16 lbs
Maximum Pump Speed: 1750 RPM
Minimum Horsepower Requirements: 9.7 BPH
Type Hollow Shaft Pump
Shaft Size 24mm (.945")
|
Fits Model |
GIANT PUMP : P316LX Short Cover
|
Replaces OEM |
Giant Pump :
|
|
|